Parameter
|
772 |
Units
|
Comments
|
LEVEL RANGES |
| Full Scale
Level Ranges |
0-35, 0-115, 0-230
(0-10, 0-35, 0-70) |
ft H2O
(m H2O) |
for
vented gage |
|
0-35, 0-69, 0-230
(0-10, 0-21, 0-70) |
ft H2O
(m H2O) |
for
absolute reference |
| Proof Pressure |
1.5
|
x FS
|
 |
| Burst Pressure |
2.0
|
x FS
|
 |
| STATIC PERFORMANCE
|
| Static Accuracy |
±0.1 |
% FSO
|
BFSL |
|
Total Error Band(1) |
±0.25 |
%FS TEB |
Total
Error from BFSL |
| Resolution |
Infinitesimal |
%FS |
 |
ENVIRONMENTAL |
| Wetted Materials |
316 SS or Titanium;
Delrin®;
polyurethane or Viton®
|
 |
Delrin®
and Viton® are registered trademarks of DuPont. |
| Compensated Temp Range |
-20 to 60
|
ºC
|
 |
| Operating Temp Range |
-20 to 60
0 to 50
|
ºC
ºC
|
when using polyurethane cable
when using ETFE cable (3) |
|
Protection Rating |
IP 68, NEMA 6P |
|
|
ELECTRICAL |
| Excitation |
9 -
30
|
VDC |
for mA
and VDC output |
| Input Current |
20
3.5
|
mA max |
for mA output
for VDC output |
| Output |
4 -
20
0.05 - 5
|
mA
VDC
|
|
| Zero Offset |
±0.12 <0.25 |
mA VDC |
for mA output
for VDC output |
| Output
Impedance |
See Loop Resistance diagram
page 7 of datasheet
510 |
ohm
|
for mA output
for VDC output |
| Insulation Resistance |
100
|
mega ohm |
at 50 VDC |
| Circuit Protection |
Polarity, surge/shorted output
|
 |
 |
TURN DOWN |
@ nominal FS |
@ 10:1 Turndown |
|
|
|
Static Accuracy (2) |
±0.1 |
±0.5 |
%FS |
|
|
Total Error Band(2) |
±0.25 |
±2 |
%FS |
|
PHYSICAL |
| Approximate Weight |
0.47 (210)
0.05 (79)
|
lbs (g)
lbs/ft (g/m) |
transducer
cable |
Cable
Jacket Material
Pull Strength
Number of Conductors
Conductor Size |
Polyurethane (std)
ETFE (4) (opt)
200 (90)
4
6
22
|
lbs (kg)
AWG |
Tefzel®, Teflon® and
Kevlar® are registered trademarks of DuPont.
mA output version
VDC output version |
| Cable
Seal |
Molded polyurethane
Viton® Gland |
|
for
polyurethane cable
for ETFE cable |