| Level Transducers (Submersible) |
Model |
|
Accuracy |
|
Description |
|
Photo |
|
Minimum
Full Scale |
|
Maximum
Full Scale |
|
Output |
|
735
730
720
710
700 |
|
±0.05% FS
±0.10% FS
±0.25% FS
±0.50% FS
±1.00% FS |
|
General purpose,
analog output |
|
 |
|
2.5 feet
(0.75
meters) |
|
700 feet
(210 meters) |
|
4-20 mA, 0-5 VDC,
mV |
|
335
330
320 |
|
±0.05% FS
±0.10% FS
±0.25% FS |
|
Small bore,
analog output |
|
 |
|
5 feet
(1.5
meters) |
|
700 feet
(210 meters) |
|
4-20 mA, 0-5 VDC,
mV |
|
|
750 |
|
±0.25% FS |
|
Non-fouling,
2.75" diaphragm,
analog output |
|
 |
|
10 feet
(3
meters) |
|
115 feet
(35 meters) |
|
4-20 mA, 0-5 VDC |
|
|
705 |
|
±0.25% FS |
|
Non-fouling,
0.90" diaphragm,
analog output |
|
|
|
6 feet
(2
meters) |
|
115 feet
(35 meters) |
|
4-20 mA, 0-5 VDC |
|
|
300DS |
|
±0.50% FS |
|
Deep water,
small bore,
analog output |
|
|
|
700 feet
(210
meters) |
|
4614 feet
(1408 meters) |
|
4-20 mA, 0-5 VDC,
mV |
|
173
169 |
|
±0.10% FS
±0.25% FS |
|
Datalogger
specific, analog output |
|
 |
|
10 feet
(3
meters) |
|
230 feet
(70 meters)
|
|
mV |
|
|
126
116
|
|
±0.10% FS
±0.30% TEB
±0.25% FS
±0.30% TEB |
|
Datalogger
specific, 6 wire analog output |
|
|
|
10 feet
(3
meters) |
|
230 feet
(70 meters) |
|
mV with voltage
sense |
|
|
343
342
|
|
±0.05% FS
±0.25% TEB
±0.10% FS
±0.25% TEB |
|
ASIC-based,
small bore,
analog output |
|
|
|
10 feet
(3
meters) |
|
230 feet
(70 meters) |
|
4-20 mA, 0-5 VDC |
|
|
772 |
|
±0.10% FS
±0.25% TEB |
|
ASIC-based,
field re-rangeable,
analog output |
|
 |
|
35 feet
(10
meters) |
|
230 feet
(70 meters) |
|
4-20 mA, 0-5 VDC |
|
|
500
501 |
|
±0.05% TEB |
|
Microcomputer-based,
digital output |
|
|
|
5 feet
(1.5
meters)
|
|
230 feet
(70 meters) 50 feet (15 meter)
|
|
SDI-12 |
|
|
waterMONITOR
|
|
±0.05% TEB |
|
Embedded
datalogger, small bore,
digital output |
|
 |
|
10 feet
(3
meters) |
|
692 feet
(210 meters) |
|
RS-485 with
SDI-12 protocol |
|
| Pressure Transducers (Non-Submersible) |
Model |
|
Accuracy |
|
Description |
|
Photo |
|
Minimum
Full Scale |
|
Maximum
Full Scale |
|
Output |
|
35
30
27
28 |
|
±0.05% FS
±0.10% FS
±0.25% FS
±0.50% FS |
|
General purpose,
analog output |
|
 |
|
1 psi
(7 kPa) |
|
2000 psi
(13,790 kPa) |
|
4-20 mA, 0-5 VDC,
mV |
|
|
200 |
|
±0.50% FS |
|
High pressure,
pressure output |
|
 |
|
2000 psi
(13.8 mPa) |
|
15,000 psi
(103.4 mPa) |
|
4-20 mA, 0-5 VDC,
mV |
|
Download KPSI Level and Transducer Selection Guide (PDF)

|
|