Esterline Pressure Systems Logo header spacer Pressure Systems Site Map Pressure Systems Home
 
 

KPSI™ Level and Pressure Transducer Selection Guide

–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
 
This transducer selection guide is intended to offer assistance in identifying transducer models that may best suit the requirement. Click on the desired Model number to view complete details regarding transducer specifications and capabilities.
Level Transducers (Submersible)
Model Accuracy
Description
Photo Minimum
Full Scale
Maximum
Full Scale
Output

735
730
720
710
700
  ±0.05% FS
±0.10% FS
±0.25% FS
±0.50% FS
±1.00% FS
 

General purpose,
analog output

   

2.5 feet
(0.75 meters)

 

700 feet
(210 meters)

 

4-20 mA, 0-5 VDC, mV


335
330
320
  ±0.05% FS
±0.10% FS
±0.25% FS
 

Small bore,
analog output

   

5 feet
(1.5 meters)

 

700 feet
(210 meters)

 

4-20 mA, 0-5 VDC, mV


750   ±0.25% FS  

Non-fouling,
2.75" diaphragm,
analog output

 

 

10 feet
(3 meters)

 

115 feet
(35 meters)

 

4-20 mA, 0-5 VDC


705   ±0.25% FS  

Non-fouling,
0.90" diaphragm,
analog output

   

6 feet
(2 meters)

 

115 feet
(35 meters)

 

4-20 mA, 0-5 VDC


300DS   ±0.50% FS  

Deep water,
small bore,
analog output

   

700 feet
(210 meters)

 

4614 feet
(1408 meters)

 

4-20 mA, 0-5 VDC, mV


173
169
  ±0.10% FS
±0.25% FS
 

Datalogger specific, analog output

 

 

10 feet
(3 meters)

 

230 feet
(70 meters)

 

mV


126


116

  ±0.10% FS
±0.30% TEB

±0.25% FS
±0.30% TEB
 

Datalogger specific, 6 wire analog output

   

10 feet
(3 meters)

 

230 feet
(70 meters)

 

mV with voltage sense


343


342

  ±0.05% FS
±0.25% TEB

±0.10% FS
±0.25% TEB
 

ASIC-based,
small bore,
analog output

   

10 feet
(3 meters)

 

230 feet
(70 meters)

 

4-20 mA, 0-5 VDC


772   ±0.10% FS
±0.25% TEB
 

ASIC-based,
field re-rangeable,
analog output

 

 

35 feet
(10 meters)

 

230 feet
(70 meters)

 

4-20 mA, 0-5 VDC


500

501

  ±0.05% TEB  

Microcomputer-based,
digital output

   

5 feet
(1.5 meters)

 

230 feet
(70 meters)
50 feet
(15 meter)

 

SDI-12


waterMONITOR

  ±0.05% TEB  

Embedded datalogger, small bore,
digital output

 

 

10 feet
(3 meters)

 

692 feet
(210 meters)

 

RS-485 with SDI-12 protocol


Pressure Transducers (Non-Submersible)
Model   Accuracy   Description   Photo   Minimum
Full Scale
  Maximum
Full Scale
  Output

35
30
27
28
  ±0.05% FS
±0.10% FS
±0.25% FS
±0.50% FS
 

General purpose,
analog output

 

 

1 psi
(7 kPa)

 

2000 psi
(13,790 kPa)

 

4-20 mA, 0-5 VDC, mV


200   ±0.50% FS  

High pressure,
pressure output

 

 

2000 psi
(13.8 mPa)

 

15,000 psi
(103.4 mPa)

 

4-20 mA, 0-5 VDC, mV


link arrow  Download KPSI Level and Transducer Selection Guide (PDF)

Adobe Reader download link


 
Pressure Systems
34 Research Drive
Hampton, VA 23666
800.678.7226
KPSI Selection Guide Quality Policy
ISO-9001:2000
Receive E-Newsletter
IPC Member Logo WEEE/RoHS Statement
WEEE/RoHS