KPSI Level & Pressure Transducers: Application Notes

Wet Well Level Transmitter

–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
 


The liquid level or pressure shall be sensed by a pressure transducer certified by FM, UL, and CSA for installation in a Class I, Division 1, Groups A, B, C, and D, Class II, Division 1, Groups E, F, and G, Class III, Division 1 hazardous location when connected to associated apparatus manufactured by R.G. Stahl and others. The transducer shall be installed in accordance with manufacturer's instructions.

The transducer shall sense the liquid level or pressure variations and convert these variations into a linear 0-5 VDC or 4-20 mA signal. The transducer shall be solid state with no mechanical linkages or moving parts. Static accuracy of ±1% includes the combined errors due to nonlinearity , hysteresis and nonrepeatability on a Best Fit Straight Line basis at 25ºC, per ISA S51.1.

The pressure sensing element shall incorporate a four active arm Wheatstone Bridge strain gage diffused directly into a silicon diaphragm. The sensed media shall exert its pressure against a 316 SS barrier diaphragm. The sensing element shall exhibit non measurable hysteresis, withstand overpressures to 200% of rated range without damage and have a life expectancy in the tens of millions of cycles.

Transducer shall operate from a 9-30 VDC regulated or unregulated power source. On-board signal conditioning shall also include overvoltage and reverse polarity protection.

The transducer housing shall be assembled with 360º circumferential welds. Wetted materials may include 316 SS and Viton only. Transducer housing diameter may not exceed 1.0 inch.

Factory-attached 0.30" OD polyurethane or Tefzel jacketed cable shall have pull strength of 200 pounds. Cable construction to include non-stretch Kevlar stiffeners, cable shield and vent tube for atmospheric reference with moisture barrier. Water tight cable seal shall be via compression type fitting.

link arrow  return to KPSI Level and Pressure Transducer Application Notes

 

 
 
Pressure Systems
34 Research Drive
Hampton, VA 23666
800.678.7226
KPSI Selection Guide Quality Policy
ISO-9001:2000
Receive E-Newsletter
IPC Member Logo WEEE/RoHS Statement
WEEE/RoHS
Statement
 


Home | Environmental Products | Industrial Products | Aerospace Products | Buy Now
KPSI Level and Pressure Selection Guide | Quartzonix Pressure Standard | NetScanner System | System 8400 |
Electronic Pressure Scanners | S8256 System | Miscellaneous Hardware | News Archive
Contact Us | Distributors | Links | Employment | Register | Search